config_manager [2019/02/22 00:14] sq3plx |
config_manager [2019/02/22 00:16] sq3plx |
||
---|---|---|---|
Line 49: | Line 49: | ||
This selects a type of digital thermometer connected to rear panel THERMO input and it allows to correctly compute the temperature based on binary measurements. | This selects a type of digital thermometer connected to rear panel THERMO input and it allows to correctly compute the temperature based on binary measurements. | ||
+ | |||
+ | After making changes we can restart the Direwolf daemon with following commands: | ||
+ | |||
+ | <code> | ||
+ | root@nanopiduo:~# service ulari-manager stop | ||
+ | root@nanopiduo:~# service ulari-manager start | ||
+ | </code> | ||
+ | or restart whole ULARI Radio Interface with: | ||
+ | <code> | ||
+ | root@nanopiduo:~# reboot | ||
+ | </code> | ||
=== Data gathered by ulari-manager === | === Data gathered by ulari-manager === | ||
ulari-manager reads sensor data from Atmega microcontroller and stores them in temporary files: | ulari-manager reads sensor data from Atmega microcontroller and stores them in temporary files: | ||
- | * /tmp/exttemp - THERMO input temperature measurement in binary format, | + | * /tmp/ulari-exttemp - THERMO input temperature measurement in binary format, |
- | * /tmp/exttemo-c - THERMO temperature converted to Celsius degrees based on number of bits defined in THERMOBITS parameter, | + | * /tmp/ulari-exttemp-c - THERMO temperature converted to Celsius degrees based on number of bits defined in THERMOBITS parameter, |
- | * /tmp/vdet - input voltage in mV. | + | * /tmp/ulari-vdet - input voltage in mV. |
+ | Above files are generated by ulari-manager when run and are updated every 1 second. |